Efficiency Normal, Light and Super-Light Loads
The platform is very efficient at normal load and light load at 115 V. It can be improved for light loads at 230 V, and the same is true for the 2% load test at 115 V.
Average Efficiency 5VSB
The 5VSB rail lags behind the competition at 230V.
Vampire Power
Vampire power is low enough at 115V, but I’d like to see under 0.1W at 230V.
Average efficiency
he average efficiency is high and meets Cybenetics Titanium requirements.
PFC (Power Factor Correction)
A power factor correction filter increases the power factor reduced by the distortion reactive power because it reduces the amount of spurious harmonics and, consequently, the mains load. The APFC converter works quite well at 115 V, but at 230 V it needs to be optimized.