Direct 1:1 Fan Comparison of two Fans

You can compare two fans in detail here. In the selection lists, you will find all fans listed in alphabetical order. This allows you to individualize the comparison as you wish. For each fan, there is also a detailed view with all the captured and measured data, down to individual reviews, sound samples, and detailed frequency analyses. For the methodology and equipment, you can find the relevant button to an extra page in the above menu, which can also be opened in a new window or tab.

Beta phase: The same applies during the beta phase, where the limitations with interpolated and restricted data from the older, initial fan tests are still in place, but we will gradually complete them over time. Any errors in the software or data entry, we ask you to forgive, and we will make the necessary adjustments as soon as possible. Please send suggestions and feedback exclusively via email to [email protected].

Test methods and equipment

Back to Overview

Compare

General

Vendor
Blacknoise
Corsair
Product name
B14x-P-BL PWM ARGB
AF120 RGB Elite
Dimension
140 mm
120 mm
Height
25 mm
25 mm
Weight
202 g
195 g

Official Datasheet

Minimum RPM
0 U/min
550 U/min
Maximum RPM
1500 U/min
2100 U/min
Min Consumption
0.5 W
0.8 W
Max Consumption
2.9 W
1.3 W
Airflow (CFM)
110.0 CFM
65.6 CFM
Airflow (m³/h)
186.0 m³/h
111.4 m³/h
Static Pressure (mmH2O)
2.30 mmH2O
1.72 mmH2O
Sound
29.6 dBA
31.0 dBA

More Information

Review
-

Features

PWM
RGB
Noise Absorption

Colors

Frame
Black
White
Highlight
-
Grey
Rotor
Transparent
Transparent

Measures DC

Start-Up Voltage
4.3 V
3.4 V
Shut-Down Voltage
3.2 V
2.9 V
Start-Up DC
335 U/min
601 U/min
Shut-Down DC
154 U/min
503 U/min

Measures PWM

Start-Up RPM
N/A
456 U/min
Shut-Down RPM
N/A
382 U/min

Other Measures

Max RPM
1487 U/min
2143 U/min
No-Stop RPM
N/A
N/A
column_boost_rpm
N/A
450 U/min

Airflow (CFM)

Case Fan (1000 RPM)
60.3 CFM
+82.2 %
33.1 CFM
Radiator 25mm (1000 RPM)
33.2 CFM
+59.5 %
20.8 CFM
Radiator 45mm (1000 RPM)
32.3 CFM
+58.7 %
20.4 CFM
Radiator 60mm (1000 RPM)
33.2 CFM
+4.4 %
31.8 CFM

Airflow (m³/h)

Case Fan (1000 RPM)
102.4 m³/h
+82.2 %
56.2 m³/h
Radiator 25mm (1000 RPM)
56.5 m³/h
+59.6 %
35.4 m³/h
Radiator 45mm (1000 RPM)
54.9 m³/h
+58.7 %
34.6 m³/h
Radiator 60mm (1000 RPM)
56.5 m³/h
+4.4 %
54.1 m³/h

Static Pressure (mmH2O)

Case Fan (1000 RPM)
1.32 mmH2O
+15.9 %
1.53 mmH2O
Radiator 25mm (1000 RPM)
1.32 mmH2O
+61.0 %
0.82 mmH2O
Radiator 45mm (1000 RPM)
1.01 mmH2O
+98.0 %
0.51 mmH2O
Radiator 60mm (1000 RPM)
1.22 mmH2O
+8.9 %
1.12 mmH2O

Static Pressure (hPa)

Case Fan (1000 RPM)
0.13 hPa
+15.4 %
0.15 hPa
Radiator 25mm (1000 RPM)
0.13 hPa
+62.5 %
0.08 hPa
Radiator 45mm (1000 RPM)
0.10 hPa
+100.0 %
0.05 hPa
Radiator 60mm (1000 RPM)
0.12 hPa
+9.1 %
0.11 hPa

Sound

Case Fan (1000 RPM)
33.7
-2.4 %
32.9
Radiator 25mm (1000 RPM)
37.4
-22.2 %
29.1
Radiator 45mm (1000 RPM)
36.6
-16.7 %
30.5
Radiator 60mm (1000 RPM)
36
-16.4 %
30.1

Airflow (m³/h) vs Static Pressure (mmH2O)

Airflow (CFM) vs Static Pressure (hPa)

Compare Sound

Case Fan
-
  • 456
  • 656
  • 856
  • 1056
  • 1256
  • 1456
  • 1656
  • 1856
  • 2056
25mm Radiator
-
  • 456
  • 656
  • 856
  • 1056
  • 1256
  • 1456
  • 1656
  • 1856
  • 2056
45mm Radiator
-
  • 456
  • 656
  • 856
  • 1056
  • 1256
  • 1456
  • 1656
  • 1856
  • 2056
60mm Radiator
-
  • 456
  • 656
  • 856
  • 1056
  • 1256
  • 1456
  • 1656
  • 1856
  • 2056

Important notes on the tests and their results

The fans tested here were either provided by the manufacturers without preconditions or come from the editorial stock or were anonymously purchased in stores. None of the tests were influenced in any way by the respective manufacturer. The test results were communicated to the manufacturers for review and comment in advance in case of abnormalities or strong contradictions to the stated technical data, and in some cases, measurements were also taken with anonymously purchased retail goods.

We explicitly point out that our laboratory cannot and does not want to produce ISO-certified measurements. The test setups with and without radiators were designed by us to be as practical as possible, in order to capture all intermediate values in the respective speed ranges. The audio recordings were normalized to also transport the smallest nuances into the audible ranges. Therefore, it may well happen that the fans seemed louder than they are. For a comparison of the absolute noise emission of two fans, the measurement curve must always be compared.

The manufacturer information used comes either from the respective packaging or from the data sheets on the respective homepages of the providers. Since we have already found several printing errors and even completely incorrect information, these values should always be viewed with the necessary skepticism if they significantly deviate from our measurements. Moreover, more than once the product has been significantly changed over time without this being publicly communicated. In this case, we ask our readers for appropriate feedback if new contradictions arise.

Werbung

Werbung